The integrated electronics simplify setup, reducing wiring and making configuration faster. Optimized energy consumption also improves thermal management, keeping motor temperatures low and extending operational life. These qualities make integrated brushless DC motors the go-to solution for users seeking high performance with minimal installation effort.

 

Code

Flange

Rated voltage
[Volt]

Drive
supply
voltage
[Vcc]

Control mode

Rated torque
[Ncm] min.

Peak torque
[Ncm]

Power [W]

Feedback

Protection
class

DM4D2200-PS1NEMA 24 - 60 mm square48.0048.00 + 24.00 for logicProgrammable Fieldbus CANbus0.521.56200Absolute multiturn encoder IP65
DM4D1026C2R1BS0d0380NEMA 17 - 42 mm square24.0024.00Fieldbus CANbus DS4026.25 26.00Hall sensor IP20
DM4D1026C2R1GM0d0380NEMA 17 - 42 mm square24.0024.00Fieldbus CANbus DS4026.25 26.00Incremental magnetic encoder and absolute single-turn IP20
DM4D1052C2R1CS0d0380NEMA 17 - 42 mm square24.0024.00Fieldbus CANbus DS40215.00 52.5Hall sensor IP20
DM4D1052C2R1HM0d0380NEMA 17 - 42 mm square24.0024.00Fieldbus CANbus DS40215.00 52.5Incremental magnetic encoder and absolute single-turn IP20
DM4D1078C2R1DS0d0380NEMA 17 - 42 mm square24.0024.00Fieldbus CANbus DS40222.00 77.5Hall sensor IP20
DM4D1078C2R1IM0d0380NEMA 17 - 42 mm square24.0024.00Fieldbus CANbus DS40222.00 77.5Incremental magnetic encoder and absolute single-turn IP20
DM4D1104C2R1ES0d0380NEMA 17 - 42 mm square24.0024.00Fieldbus CANbus DS40230.00 104,0Hall sensor IP20
DM4D1104C2R1LM0d0380NEMA 17 - 42 mm square24.0024.00Fieldbus CANbus DS40230.00 104,0Incremental magnetic encoder and absolute single-turn IP20
DM4D1046C2R5BS0d0380NEMA 23 - Ø 57 mm round36.0036.00Fieldbus CANbus DS40211.00 46.0Hall sensor IP20
DM4D1046C2R5GM0d0380NEMA 23 - Ø 57 mm round36.0036.00Fieldbus CANbus DS40211.00 46.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1092C2R5CS0d0380NEMA 23 - Ø 57 mm round36.0036.00Fieldbus CANbus DS40222.00 92.0Hall sensor IP20
DM4D1092C2R5HM0d0380NEMA 23 - Ø 57 mm round36.0036.00Fieldbus CANbus DS40222.00 92.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1134C2R5DS0d0380NEMA 23 - Ø 57 mm round36.0036.00Fieldbus CANbus DS40232.00 134.0Hall sensor IP20
DM4D1134C2R5IM0d0380NEMA 23 - Ø 57 mm round36.0036.00Fieldbus CANbus DS40232.00 134.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1184C2R5ES0d0380NEMA 23 - Ø 57 mm round36.0036.00Fieldbus CANbus DS40243.00 184.0Hall sensor IP20
DM4D1184C2R5LM0d0380NEMA 23 - Ø 57 mm round36.0036.00Fieldbus CANbus DS40243.00 184.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1026C2R1BS0d0390NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus CANbus6.25 26.00Hall sensor IP20
DM4D1026C2R1GM0d0390NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus CANbus6.25 26.00Incremental magnetic encoder and absolute single-turn IP20
DM4D1052C2R1HM0d0390NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus CANbus15.00 52.5Incremental magnetic encoder and absolute single-turn IP20
DM4D1104C2R1ES0d0390NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus CANbus30.00 104,0Hall sensor IP20
DM4D1104C2R1LM0d0390NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus CANbus30.00 104,0Incremental magnetic encoder and absolute single-turn IP20
DM4D1078C2R1DS0d0390NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus CANbus22.00 77.5Hall sensor IP20
DM4D1078C2R1IM0d0390NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus CANbus22.00 77.5Incremental magnetic encoder and absolute single-turn IP20
DM4D1052C2R1CS0d0390NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus CANbus15.00 52.5Hall sensor IP20
DM4D1046C2R5BS0d0390NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus CANbus11.00 46.0Hall sensor IP20
DM4D1046C2R5GM0d0390NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus CANbus11.00 46.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1092C2R5CS0d0390NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus CANbus22.00 92.0Hall sensor IP20
DM4D1092C2R5HM0d0390NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus CANbus22.00 92.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1134C2R5DS0d0390NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus CANbus32.00 134.0Hall sensor IP20
DM4D1134C2R5IM0d0390NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus CANbus32.00 134.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1184C2R5ES0d0390NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus CANbus43.00 184.0Hall sensor IP20
DM4D1184C2R5LM0d0390NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus CANbus43.00 184.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1026M2R1BS0d0490NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus Modbus RTU6.25 26.00Hall sensor IP20
DM4D1026M2R1GM0d0490NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus Modbus RTU6.25 26.00Incremental magnetic encoder and absolute single-turn IP20
DM4D1052M2R1CS0d0490NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus Modbus RTU15.00 52.5Hall sensor IP20
DM4D1052M2R1HM0d0490NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus Modbus RTU15.00 52.5Incremental magnetic encoder and absolute single-turn IP20
DM4D1104M2R1ES0d0490NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus Modbus RTU30.00 104,0Hall sensor IP20
DM4D1104M2R1LM0d0490NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus Modbus RTU30.00 104,0Incremental magnetic encoder and absolute single-turn IP20
DM4D1078M2R1DS0d0490NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus Modbus RTU22.00 77.5Hall sensor IP20
DM4D1078M2R1IM0d0490NEMA 17 - 42 mm square24.0024.00Programmable Fieldbus Modbus RTU22.00 77.5Incremental magnetic encoder and absolute single-turn IP20
DM4D1046M2R5BS0d0490NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus Modbus RTU11.00 46.0Hall sensor IP20
DM4D1046M2R5GM0d0490NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus Modbus RTU11.00 46.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1092M2R5CS0d0490NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus Modbus RTU22.00 92.0Hall sensor IP20
DM4D1092M2R5HM0d0490NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus Modbus RTU22.00 92.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1134M2R5DS0d0490NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus Modbus RTU32.00 134.0Hall sensor IP20
DM4D1134M2R5IM0d0490NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus Modbus RTU32.00 134.0Incremental magnetic encoder and absolute single-turn IP20
DM4D1184M2R5ES0d0490NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus Modbus RTU43.00 184.0Hall sensor IP20
DM4D1184M2R5LM0d0490NEMA 23 - Ø 57 mm round36.0036.00Programmable Fieldbus Modbus RTU43.00 184.0Incremental magnetic encoder and absolute single-turn IP20
LMED3B1NEMA 17 - 42 mm square24.0024.00Voltage/Speed analog reference6.25 26.00Hall sensor IP30
LMED3C1NEMA 17 - 42 mm square24.0024.00Voltage/Speed analog reference12.50 52.00Hall sensor IP30
LMED3D1NEMA 17 - 42 mm square24.0024.00Voltage/Speed analog reference18.50 78.00Hall sensor IP30
LMED3E1NEMA 17 - 42 mm square24.0024.00Voltage/Speed analog reference25.00 104.00Hall sensor IP30
LMED5B1NEMA 23 - Ø 57 mm round36.0036.00Voltage/Speed analog reference11.00 46.00Hall sensor IP30
LMED5C1NEMA 23 - Ø 57 mm round36.0036.00Voltage/Speed analog reference22.00 92.00Hall sensor IP30
LMED5D1NEMA 23 - Ø 57 mm round36.0036.00Voltage/Speed analog reference32.00 134.00Hall sensor IP30
LMED5E1NEMA 23 - Ø 57 mm round36.0036.00Voltage/Speed analog reference44.00 184.00Hall sensor IP30